From: | Nicolas Richard |
Subject: | bug#17349: 24.3.50; display-battery-mode stops updating after closing and reopening lid |
Date: | Sun, 27 Apr 2014 09:59:09 +0200 |
User-agent: | Gnus/5.13 (Gnus v5.13) Emacs/24.3.50 (gnu/linux) |
Peter Münster <pmlists@free.fr> writes: >> (I'm now running a piece of advice to check whether timer-event-handler >> is run when the problem appears, but I did not use my laptop a lot the >> last few hours.) > > Could you send it please? Perhaps it would make sense to use this advice > here on my emacs too. Sure ; although it's less useful that what its description promises. (defun yf/checktimer-after (timer) (when (eq battery-update-timer timer) (message "Ran battery update timer. current time: %s triggered-p: %s" (decode-time) (timer--triggered timer)))) (defun yf/checktimer-before (timer) (when (eq battery-update-timer timer) (message "Running battery update timer. current time: %s triggered-p: %s" (decode-time) (timer--triggered timer)))) (advice-add 'timer-event-handler :before 'yf/checktimer-before) (advice-add 'timer-event-handler :after 'yf/checktimer-after) (defun yf/checktimer-warn () (when (timer--triggered battery-update-timer) (warn "battery-update-timer has trigger flag to t."))) (add-hook 'post-command-hook 'yf/checktimer-warn) -- Nico.