bug-guix
[Top][All Lists]
Advanced

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

bug#57490: UPower ignores ‘critical-power-action’


From: Ludovic Courtès
Subject: bug#57490: UPower ignores ‘critical-power-action’
Date: Mon, 05 Sep 2022 14:56:04 +0200
User-agent: Gnus/5.13 (Gnus v5.13) Emacs/28.1 (gnu/linux)

Hi,

Ludovic Courtès <ludo@gnu.org> skribis:

> One issue remains: UPower should have called elogind’s “PowerOff” method
> for ordered shutdown before total power outage, but either that didn’t
> happen or elogind didn’t do it right (which is weird, because ‘loginctl
> poweroff’ DTRT.)

I pushed these patches:

  eedf71f948 * services: upower: Default to a percentage-based policy.
  4765242540 * services: upower: Update default percentage values.

I’m not sure whether they help, but they might: using a
time-estimate-based policy is documented as less reliable, and I suppose
even less so when a battery gets old, as is the case on this laptop.

I’d like to test whether UPower invokes the intended critical action,
but I’m not sure how to simulate a low battery level.  Thoughts?

Thanks,
Ludo’.