[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: cfd doesn't accept any more connections (1.6.3)
From: |
David Ressman |
Subject: |
Re: cfd doesn't accept any more connections (1.6.3) |
Date: |
Wed, 20 Jun 2001 13:19:30 -0500 |
User-agent: |
Mutt/1.2.5i |
Thus spake Oliver Cook (ollie@uk.clara.net):
> After cfd has been running for about a week to 10 days
> or so (sometimes more), cfd will stop accepting packets
> from cfengine clients. cfd cannot be killed with a SIGTERM
> but a SIGKILL has to be used to kill the process. It
> will then restart normally and work for the next 7-10 days.
We get something similar, although it hasn't ever been enough of a
problem to spend much time on. We run cfd 1.6.3 on OpenBSD 2.6 and
2.8, and about once every month or two, this exact problem will
occur. The next time it happens, I'll do a little more poking
around.
Re: cfd doesn't accept any more connections (1.6.3),
David Ressman <=