From: | Rik |
Subject: | [Octave-bug-tracker] [bug #59708] insersect() with options 'rows' and 'legacy' returns result with wrong orientation |
Date: | Thu, 17 Dec 2020 17:27:02 -0500 (EST) |
User-agent: | Mozilla/5.0 (X11; Linux x86_64) AppleWebKit/537.36 (KHTML, like Gecko) Chrome/87.0.4280.66 Safari/537.36 |
Update of bug #59708 (project octave): Status: Confirmed => Fixed Open/Closed: Open => Closed _______________________________________________________ Follow-up Comment #2: I fixed the problem in intersect and also in setxor. The rest of the set functions behaved correctly with "rows" and "legacy" options present. I checked the change in on the stable branch of Octave here: http://hg.savannah.gnu.org/hgweb/octave/rev/7f11d59e3af8. This will be a port of the 6.1.1 bug fix release. _______________________________________________________ Reply to this item at: <https://savannah.gnu.org/bugs/?59708> _______________________________________________ Message sent via Savannah https://savannah.gnu.org/