octave-bug-tracker
[Top][All Lists]
Advanced

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

[Octave-bug-tracker] [bug #59149] [octave forge] (signal) Resampling fro


From: Markus Mützel
Subject: [Octave-bug-tracker] [bug #59149] [octave forge] (signal) Resampling from 22050 to 48000 Hz introduces strange and unexpected artifacts
Date: Fri, 22 Apr 2022 02:44:08 -0400 (EDT)

Follow-up Comment #55, bug #59149 (project octave):

To avoid the issue on platforms where `octave_idx_type` is not `long` that
Philip was mentioning in comment #51, the attached patch could probably be
used. (Untested!)

(file #53129)

    _______________________________________________________

Additional Item Attachment:

File name: bug59149-idx_type.patch        Size:1 KB
    <https://file.savannah.gnu.org/file/bug59149-idx_type.patch?file_id=53129>



    _______________________________________________________

Reply to this item at:

  <https://savannah.gnu.org/bugs/?59149>