On Tue, 21 Dec 2004, Michael Anburaj wrote:
Let me know if I missed something or if I uncovered a
bug.

I think you've missed something I'm afraid! TIME_WAIT lasts for 120 seconds, so the code is correct as it stands. The maximum segment lifetime (MSL) is much longer than you think, which is I think where you introduce an error. If you want to know the reasons behind this I can provide some references to explain in more detail.

Kieran