From: | Markus Mützel |
Subject: | [Octave-bug-tracker] [bug #61752] unique.m FAIL in test suite |
Date: | Mon, 3 Jan 2022 14:37:13 -0500 (EST) |
User-agent: | Mozilla/5.0 (Windows NT 10.0; Win64; x64) AppleWebKit/537.36 (KHTML, like Gecko) Chrome/96.0.4664.110 Safari/537.36 Edg/96.0.1054.62 |
Follow-up Comment #10, bug #61752 (project octave): That is expected. Symbol visibility on Windows was broken until late December. Octave always exported all symbols independent of the configure switches. Bug #61711 only appears with visibility flags. _______________________________________________________ Reply to this item at: <https://savannah.gnu.org/bugs/?61752> _______________________________________________ Message sent via Savannah https://savannah.gnu.org/
[Prev in Thread] | Current Thread | [Next in Thread] |